Displaying report 1-1 of 1.
Reports until 12:53, Tuesday 28 November 2023
H1 ISC (CDS, DAQ)
fernando.mera@LIGO.ORG - posted 12:53, Tuesday 28 November 2023 (74451)
Continuous reading in 1CH thermistor card in SQZ 4

F. Mera, D. Sigg, M. Pirello

Per WP11548:

The Squeezer 4 rack was modified duplicating the EL3692 terminals in the positions M13, M14, M19 and M20. Wiring was modified to have readings in CH1 only.

TwinCAT solution was updated accordingly, the system was restarted and succesfully verified with the new configuration.

SQZ 4 rack serial: S2101205

Displaying report 1-1 of 1.