CDS Maintenance Summary: Tuesday 28th November 2023

WP11540 Remove SDF safe->OBSERVE exceptions for h1seiproc and h1brs

TJ, Jim:

TJ made changes to guardian to remove the exception that h1seiproc and h1brs do not transition to OBSERVE.snap. h1brs OBSERVE==safe, h1seiproc has a separate OBSERVE.snap which Jim will verify is correct.

WP11546 New FMCS STAT code base

Erik:

Erik rewrote the FMCS STAT IOC to use this new softIOC python module. The code was restarted.

New Guardian node

Camilla, Dave:

Camilla started a new Guardian nodel called SQZ_ANG_ADJUST. I updated the H1EPICS_GRD.ini file. DAQ+EDC restart was required.

DAQ Restart:

Jonathan, Erik, Dave:

The DAQ was restarted to include the new GRD channels into the EDC. This was a good restart with no issues.

cdsioc0 reboot

Erik, Dave:

Erik updated and rebooted cdsioc0. There were some issues getting Picket Fence running again, which Erik resolved. We were reminded that I was running a temporary HWS ETMY IOC in a tmux session, Erik switched this over to a systemd service via puppet.

Comments related to this report
david.barker@LIGO.ORG - 08:10, Wednesday 29 November 2023 (74469)

Tue28Nov2023
LOC TIME HOSTNAME     MODEL/REBOOT
12:12:04 h1daqdc0     [DAQ] <<< 0-leg restart
12:12:13 h1daqfw0     [DAQ]
12:12:13 h1daqtw0     [DAQ]
12:12:14 h1daqnds0    [DAQ]
12:12:22 h1daqgds0    [DAQ]


12:12:35 h1susauxb123 h1edc[DAQ] <<< EDC restart for GRD


12:20:44 h1daqdc1     [DAQ] <<< 1-leg restart
12:20:56 h1daqfw1     [DAQ]
12:20:57 h1daqtw1     [DAQ]
12:20:58 h1daqnds1    [DAQ]
12:21:07 h1daqgds1    [DAQ]
 