FCT Augmentation Update, Installation of More O-ring Valves

(Jordan V., Gerardo M.)
Late entry.
Last Tuesday Jordan and I installed 4 o-ring valves on the following crosses, FC-C2, FC-C3, FC-C4 and FC-C5.
All o-ring valves were installed on the +X 2.75" CF port for all crosses, all valves were leak tested and all new joints passed.

 