Reports until 01:29, Saturday 02 December 2023
H1 General (CDS, DetChar, OpsInfo, SEI, SQZ, SUS)
corey.gray@LIGO.ORG - posted 01:29, Saturday 02 December 2023 - last comment - 11:05, Tuesday 05 December 2023(74536)
H1 Back to Observing After Storms, Drifts, & Clipping

It's not pretty, but H1 is back in OBSERVING; range started at 143 (but it's been nosediving the last 15min to 100Mpc).  Surprised to see violin modes looking fairly normal (even after being out of lock for a while and with the high useism). 

SDF Diffs (see attach#1):  Accepted difs for SUS: ITMx, ITMy, & BS as well as SEI:  ETMx Sensor Correction

Also needed to restart the nuc30 ALIGO DARM dtt session because it Timed Out.

Microseism is still pretty high solidly on the 95th percentile mark.

Wireless Access Point in the LVEA was ON, so I turned it OFF.  I left the WAP in the MSR ON.SQZ ASC AS42 not on?? Please RESET_SQZ_ASC

DARM (see attach#2) is elevated from 10-70Hz (the reason for the low range) and also broadly at high frequency....since this looked Squeezer-ish, I checked the squeezer to see that the SQZ MANAGER had a notification about "SQZ ASC AS42 not on?? Please RESET_SQZ_ASC".  When I saw this, I was just about to post something in CHAT, but saw that Naoki was already on it and posted a CHAT asking if I could take H1 out of OBSERVING for him to reset SQZ_ASC, so I did and a few minutes later I took H1 back to OBSERVING.  Now our range should look better...it's already back above 140Mpc!  :)

Taking GRD-IFO to AUTO & H1-Manager to LOW NOISE.

Still see DARM higher from about 10-55Hz.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 11:05, Tuesday 05 December 2023 (74605)
If Naoki hadn't been available, the Troubleshooting SQZ wiki (Justin's > OPs wiki > Troubleshooting SQZ) shows there's instructions for the message "SQZ ASC AS42 not on??"  in alog 71083.