Reports until 16:16, Saturday 02 December 2023
H1 General
anthony.sanchez@LIGO.ORG - posted 16:16, Saturday 02 December 2023 (74549)
Saturday Day Shift End

TITLE: 12/03 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: Corey
SHIFT SUMMARY:
 

Removing offsets that were applied yesterday.

ITMX
H1:SUS-ITMX_M0_TEST_V_OFFSET was set back to 0.
H1:SUS-ITMX_R0_TEST_V_OFFSET was set back to 0.

ITMY
H1:SUS-ITMY_M0_TEST_V_OFFSET was set back to 0.
H1:SUS-ITMX_R0_TEST_V_OFFSET was set back to 0.

and Beam Splitter's H1:SUS-BS_M1_TEST_V_OFFSET was set back to 0.
H1:SUS-BS_M1_TEST_V_SW1 was turned OFF

I Accepted all the SDFs for these channels, screenshot1 and screenshot2


After this I put ISC_LOCK into Manual green arms and Started to search for Light on ASL-Y arm. Fought with that for a while, until I realized that the Beam splitter needs to be aligned FIRST, which made getting good flashed on the arms much simpler.
Once I got good Flashes on both arms I started an inital alignment.

Initial Alignment completed, and it did go through SR2_ALIGN.

Started Locking! Got Past AQUIRE_DRMI_1F and we are currently at ENGAGE_ASC_FOR_FULL_IFO!

LOG:
Tony went to EX to UnTrip the Hardware Watchdog
Mike was giving a tour today.

Images attached to this report