CDS Maintenance Summary: Tuesday 5th December 2023

WP11562 Reduce SUS EX SWWD countdown period

Dave, Erik, Jonathan, TJ:

As a follow on from the EX HWWD trip early Sat morning, we reduced the time for the SUS SWWD to issue its DACKILL from 20 minutes to 15 minutes.

This will mean that the SUS SWWD will trip 5 minutes before the HWWD.

The SWWD timers are hard coded (by design) in the IOP models. I created a new h1iopsusex with the second timer changed from 900 seconds (15 mins) to 600 seconds (10 mins). Adding this to the first timer of 5 mins gives us the required 15 mins.

In theory this just needed a restart of the models on h1susex, but it did not go well.

The models were stopped with 'rtcds stop --all'.

The h1iopsusex model was started, I verfied the timer change was installed (it was)

I restarted the models h1susetmx, h1sustmsx, h1susetmxpi. So far so good.

I did a list check with 'rtcds status' and was just about to logout when h1susex completely locked up.

h1iopsusex started at 11:58:46, lockup was at 12:00:50 (2min 4sec later)

There was no recourse except to remotely power cycle h1susex via its IPMI port. It was fenced from the dolphin switch before power was cycled.

Comments related to this report
david.barker@LIGO.ORG - 15:34, Tuesday 05 December 2023 (74624)

Tue05Dec2023
LOC TIME HOSTNAME     MODEL/REBOOT
11:58:31 h1susex      h1iopsusex  
11:58:54 h1susex      h1susetmx   
11:59:13 h1susex      h1sustmsx   
11:59:35 h1susex      h1susetmxpi 
12:08:27 h1susex      ***REBOOT*** <<< power cycle following computer lock up
12:10:39 h1susex      h1iopsusex  
12:10:52 h1susex      h1susetmx   
12:11:05 h1susex      h1sustmsx   
12:11:18 h1susex      h1susetmxpi