Reports until 13:35, Friday 08 December 2023
H1 SQZ
camilla.compton@LIGO.ORG - posted 13:35, Friday 08 December 2023 - last comment - 16:40, Friday 08 December 2023(74688)
No SQZ ASC for the start of this lock

Naoki, Sheila, Camilla

We changed the sqzparms use_ifo_as42_asc flag to False for this lock to watch SQZ without IFO ASC now we have the sqz angle feedback 74485. FC ASC left on. Not accepting the sdf's as we plan turn ASC back on at the end of commissioning.

Comments related to this report
naoki.aritomi@LIGO.ORG - 16:40, Friday 08 December 2023 (74692)

We turned back on SQZ ASC and changed back the SQZ ASC flag in sqzparams. The SQZ ASC was turned off from 12/08 21:26:35 UTC to 12/09 00:35:24 UTC.