keita.kawabe@LIGO.ORG - posted 18:35, Friday 16 August 2013 (7470)
TMS vertical safety wire is at a wrong position

Another ugly work around.

Mounting position of TMS vertical safety wire is shifted by about half an inch from the center of the TMS table. I'm guessing that the mounting hole position for the wire on the safety support beam, type 01 (D1100264) is wrong.

I'm bending the safety wire, as it is more like a thin rod, so that it clears the ring on the TMS tele.

The first picture shows how the safety wire is bent and the safety wire clamp tilted to allow the wire to clear the ring.

The second picture shows that a plumb bob, which is suspended from the center of the safety wire clamp, is pointing almost at the edge of the ring. 

The third picture shows how I held the plumb bob.

Images attached to this report