Added triggering to ASCIMC
I added a triggering feature similar to what the lsc has to the h1ascimc model - except that I kept it simple by defining only one trigger and one FM trigger and mask for all DoFs.

Relevant channels:

Setting the TRIGGER threshold for turning the WFS feed-back ON and OFF:
H1:IMC-TRIG_THRESH_ON
H1:IMC-TRIG_THRESH_OFF
Corresponding monitor channel:
H1:IMC-TRIG_MON      

Setting the TRIGGER threshold for turning DoF filters ON and OFF:
H1:IMC-DOF_FM_TRIG_THRESH_ON
H1:IMC-DOF_FM_TRIG_THRESH_OFF
Corresponding monitor channels:
H1:IMC-DOF_FM_TRIG_MON      
H1:IMC-DOF_FM_TRIG_MON_WORD
Corresponding MASK channels:
H1:IMC-DOF_MASK_FMx
H1:IMC-DOF_MASK_MON

I set both up to trigger at the same level as the lsc (ON=1000, OFF=900), and triggered the integrators in FM2.
This makes the ASCIMC WFS completely autonomous - no scripts required to start them up.