TITLE: 12/11 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Austin
SHIFT SUMMARY: Just got back into Observing at 07:59UTC after relocking. Two locklosses during my shift, but both were quick to recover from. SEI_CONF is back to WINDY since USEISM is down.
LOG:
00:00UTC Detector Observing and Locked for 17.5 hours
00:47 Lockloss (74725)
-- Relocking --
00:58 Manually aligned green arms, and then started an Initial Alignment
01:21 Initial Alignment completed, relocking
- Watched ISC_LOCK log, ADS, and saturation overview screen closely between LOWNOISE_COIL_DRIVERS and LOWNOISE_LENGTH_CONTROL in case we lost lock during TRANSITION_FROM_ETMX, but we were fine
02:00 NOMINAL_LOW_NOISE
-- Relocking End --
02:06 Observing
04:10 Changed SEI_CONF to WINDY due to lowering useism
- Went into the SEI_ENV code beforehand and swapped the SEI_CONF nominal states back to WINDY and EARTH_QUAKE from USEISM and USEISM_EARTHQUAKE(see 74727).
00:47 Lockloss (74728)
-- Relocking --
07:18 Earthquake mode activated due to incoming earthquake from Tonga
07:28 Back to CALM
07:55 NOMINAL_LOW_NOISE
-- Relocking End --
07:59 Observing
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 01:00 | PEM | Robert | LVEA | Y | Turn off laser vibrometer | 01:18 |