Displaying report 1-1 of 1.
Reports until 06:49, Wednesday 13 December 2023
H1 CDS
thomas.shaffer@LIGO.ORG - posted 06:49, Wednesday 13 December 2023 - last comment - 11:10, Wednesday 13 December 2023(74774)
h1iopseib3 ADC error

Looks like the lock loss was caused by an ADC error on h1iopseib3. Erik is currently working on the issue.

Comments related to this report
erik.vonreis@LIGO.ORG - 07:23, Wednesday 13 December 2023 (74775)

[ TJ, Erik, Richard ]

Failure happend at 13:16:22 UTC. 

The second ADC showed timeout.  On reboot of the front end, the Linux kernel crashed.

Richard cycled power on the IO Chassis and we rebooted the front end again.  This time it did not crash, but could not see the second DAC.

This sounds similar to the events a year ago described here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=66570

Richard is going to re-seat the second DAC.

erik.vonreis@LIGO.ORG - 07:28, Wednesday 13 December 2023 (74776)

Richard found that the LEDs on the second DAC did not come up as they did with the first DAC.  The second DAC again did not appear on the PCI bus.

Richard is going to replace it.

erik.vonreis@LIGO.ORG - 08:03, Wednesday 13 December 2023 (74777)

We're back up and running with the new DAC.

filiberto.clara@LIGO.ORG - 11:10, Wednesday 13 December 2023 (74783)

16 Bit DAC Installed: SN 180904-122
16 Bit DAC Removed: SN 100922-07

Displaying report 1-1 of 1.