Displaying report 1-1 of 1.
Reports until 14:07, Thursday 14 December 2023
H1 General (CAL)
ibrahim.abouelfettouh@LIGO.ORG - posted 14:07, Thursday 14 December 2023 - last comment - 14:49, Thursday 14 December 2023(74814)
Lockloss 21:19 UTC - While Taking Simuline Calibration Measurements

21:18- UTC - Calibration Measurement (simuLines) started. 

21:19 - UTC - Lost Lock

Potentially (but unlikely) related - Oli also lost lock during Simulines during their shift - alog 74716

Relocking Now as of 21:20 UTC.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 14:26, Thursday 14 December 2023 (74815)

Attached shows that the sus excitations began shortly before the oscillation begain, but that the DARM1 and SWEPTSINE excitations began after the oscillation.  Investigation still ongoing as to what caused the lockloss though.

Images attached to this comment
camilla.compton@LIGO.ORG - 14:49, Thursday 14 December 2023 (74818)

We plotted the fast 16kHz channel of H1:SUS-ETMX_L2_CAL_EXC_OUT_DQ and can see this excitation caused the ETMX oscillation and lockloss. Sheila/Jenne state this is not that surprising as the gains have been changed the ETMX filters. Plot attached.

Images attached to this comment
Displaying report 1-1 of 1.