TITLE: 12/14 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Tony
SHIFT SUMMARY:
IFO is in NLN and COMMISSIONING
17:56:40: Range Loss Investigation
- Dropped out of observing temporarily for 2 seconds from 17:56:40 UTC to 17:56:38 UTC. Brief investigation showed that there was a brief SDF diff in SUSETMX. There also appeared to be a BLRMs glitch around then as well as a OMC DCPD spike.
- Oli also noticed that the range dropped before the SUSETMX diff and trending this implies that the diff happened as a cause of the range drop, which then may imply that the range drop happened due to the BLRMs glitch. Note that since the range monitor is on a one minute trend, we can’t tell if the range drop happened exactly at 17:55 UTC or in the minute prior, so if this is the “first cause”, it would be hard to know.
- These have not caused SDF diffs in the past though, so will continue investigating.
- Investigating the BLRMs shows that there was a glitch at 17:54 UTC in all but 1-2khz range BLRMs. This implies that indeed the range drop was caused by a BLRMs glitch that did not register on the scope until the monitor updated its minute trend. This then could be a completely unrelated issue.
- The OMC DCPD Window also expectedly shows a glitch at the same time around 17:53:52.
- I’ll keep an eye out if this happens again. Feel free to investigate further. Screenshots below.
(4 Screenshots)
20:45 UTC - Started running calibration measurements (1 screenshot)
- Note: New configuration for EX was active during all calibration measurements
20:50 UTC - Broadband calibration measurement started
- Note: Feedforward was off during broadband calibration
21:18- UTC - Next calibration (simuLines) started.
21:19 - UTC - lost lock (alog 74814)
21:20 UTC - Relocking
21:27 UTC - Nds0 daqd restarted by Dave right after lockloss - caused all ndscopes to stall and require resetting.
22:37 UTC - Air handler red alarm started blaring. Eric was the last person in there earlier to check on these. I called him and he’s investigating. Trends show that it was off for about 15 minutes. Alarm is back to normal as of 14:50 UTC.
23:08 - Reached NLN - Resumed commissioning.
LOG:
| Start Time |
System |
Name |
Location |
Lazer_Haz |
Task |
Time End |
| 22:11 |
FAC |
Eric |
CS |
N |
Check air handlers |
22:21 |
| 19:45 |
FAC |
Kim |
LVEA External Rollup Door |
N |
Cardboard Haul |
20:45 |
| 19:45 |
FAC |
Karen |
Woodshop |
N |
Technical Cleaning |
19:55 |
| 18:38 |
FAC |
Karen |
Vac Prep |
N |
Technical Cleaning |
19:38 |
| 17:41 |
FAC |
Cindi |
Wood shop area |
N |
Laundry |
18:41 |
| 17:42 |
|
Nutsinee |
Optics Lab |
Local |
Testing |
18:38 |
| 16:43 |
FAC |
Karen, Kim, Randy |
Garb Storage |
N |
Assessing inventory |
16:43 |