I moved the vacuum VME crate for the X beam manifold (h0velx) over to the new boot server today, as specified in WP 4090. This move did not go as smoothly as the one for LY. Two issues: 1) The paths in the startup file pointed to /src - all the other files have referenced /cvs instead, I'm not sure why this one is different; it may be that the startup file for this crate had been updated with the 'new' fs scheme (/src) at some point, but the others never were (/cvs). In any event, I need to re-scrub all the startup files to verify they point to the correct place on vxboot (/cvs in this case). 2) The 2210 VME card failed on reboot - this is the relay/BIO board. The symptom was that the fail light would not go out once the crate was booted. Tried re-seating the card (which did not work), so the card was swapped out with a spare. One symptom of this failure was that the CP fill valve went open to 100%; it's not clear if this is the design intent, or a side effect of how the card failed. In any event, h0velx is now running as expected from the new server.