Moved h0velx over to new boot server
I moved the vacuum VME crate for the X beam manifold (h0velx) over to the new boot server today, as specified in WP 4090.  This move did not go as smoothly as the one for LY.  Two issues:

1) The paths in the startup file pointed to /src - all the other files have referenced /cvs instead, I'm not sure why this one is different; it may be that the startup file for this crate had been updated with the 'new' fs scheme (/src) at some point, but the others never were (/cvs).  In any event, I need to re-scrub all the startup files to verify they point to the correct place on vxboot (/cvs in this case).

2) The 2210 VME card failed on reboot - this is the relay/BIO board.  The symptom was that the fail light would not go out once the crate was booted.  Tried re-seating the card (which did not work), so the card was swapped out with a spare.  One symptom of this failure was that the CP fill valve went open to 100%; it's not clear if this is the design intent, or a side effect of how the card failed.

In any event, h0velx is now running as expected from the new server.