Reports until 09:08, Tuesday 19 December 2023
H1 ISC (IOO, OpsInfo)
ryan.short@LIGO.ORG - posted 09:08, Tuesday 19 December 2023 (74893)
Centered IMC WFS

Over the past few weeks we've occasionally been seing the notice on DIAG_MAIN that the IMC WFS need to be centered, so I did that during the maintenance window this morning, The process was as follows:

  1. Offload IMC WFS by taking IMC_LOCK to 'MCWFS_OFFLOADED'
  2. Take IMC_LOCK to 'OFFLINE'
  3. Using the MCWFS centering scope and picomotors on the IMC overview screen, center the signal on each WFS
  4. Accept IMC PZT offset SDFs from the previous offloading

I'm leaving the IMC offline for SQZ/OMC scans.

Images attached to this report