jenne.driggers@LIGO.ORG - posted 14:33, Wednesday 20 December 2023 - last comment - 00:55, Thursday 21 December 2023(74941)
Stochastic hardware injections run in coincidence with LLO

[Jenne, RyanS, JoeB remote at LLO]

We've started the 45 min stochastic magnetic injection set after having recently reacquired lock.

We turned on the amplifier in the LVEA by clicking the ON button on H1:CDS-PULIZZI_ACPWRCTRL_VERTEX0_OUTLET_1 (sitemap -> CDS -> CDS AC Power Control), then put in the same gps time (1387146396) as LLO into the script from userapps/pem/h1/scripts/inject_mag_10to40.py, which is using waveform = 'CorrMagInj_timestream_2700sec.dat'.

The attached screenshot shows the vertex magnetometers and a (not necessarily well calibrated) version of DARM with the references before the injections, and the 'live' traces during a time of the injection.

This will run for about 45 mins, then we'll turn off the amplifier and go to Observing for the night.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 15:16, Wednesday 20 December 2023 (74945)

This is finished.  I turned off the amplifier, and reset the gain H1:PEM-CS_GDS_0_GAIN back to its nominal value of 1.0, then RyanS took us to Observing.

kamiel.janssens@LIGO.ORG - 00:55, Thursday 21 December 2023 (74955)

Injection was succesfull and is coherently recovered in magnetometers as well as h(t).

Fig1 &2: Hx magnetometer - Lx magnetometer: Coherence/CSD, before, during and after injection

Fig3 &4: H strain - Lstrain: Coherence/CSD, before, during and after injection

 

Channels used:

Hx mag = H1:PEM-CS_MAG_LVEA_VERTEX_X_DQ

Lx mag = L1:PEM-CS_MAG_LVEA_VERTEX_X_DQ

H strain =H1:GDS-CALIB_STRAIN

L strain = L1:GDS-CALIB_STRAIN

Times used:

Before: start: 1387126878 (Dec 20 - 17:01:00 UTC) - duration: 43min, 10 sec fft, 50% overlap (since no good period of coincident lock just before injection, I took the last part of previous lock)

Injection: start gps = 1387146456 (Dec 20 - 22:27:18  UTC) - duration: 43min, 10 sec fft, 50% overlap

After: start: (Dec 21 - 02:01:00 UTC) - duration: 43 min, 10 sec fft, 50% overlap (since no good period of coincident lock just after injection, I took the first part of next lock)