Displaying report 1-1 of 1.
Reports until 14:27, Tuesday 26 December 2023
H1 General (Lockloss, VE)
anthony.sanchez@LIGO.ORG - posted 14:27, Tuesday 26 December 2023 - last comment - 11:46, Thursday 04 January 2024(75043)
Ops Mid Day report

STATE of H1: Observing at 154Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 5mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.94 μm/s
QUICK SUMMARY:

InLock Sus charge measurements likely caused the lockloss this morning. Though there was a PI message at the same time. but the PI didn't seem high enough to break a lock.
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1387641172

Relocking  started before 1600UTC.
16:45 UTC NOMINAL_LOW_NOISE reached and OBSERVING at 16:51 UTC

SQZ manager dropped us into commissioning at 17:22 UTC
Back to Observing at 17:24 UTC

N2 truck arrived at Y end around 17:34.
I missed the time that the N2 truck left. I believe it was shortly after 1900 UTC

The Temps in the in the VPW ranged from 66F to 73F. Im not sure what the correct range should be, but the one that read 73 was nearest the warmed server exhaust on that side of the room.

Comments related to this report
gerardo.moreno@LIGO.ORG - 17:22, Tuesday 26 December 2023 (75046)DetChar-Request, PEM, VE

Attached is a plot of today's noisy events related to the LN2 delivery to the tank for CP7.  Since the IFO was locked flagging the respective groups.

Non-image files attached to this comment
camilla.compton@LIGO.ORG - 16:45, Wednesday 03 January 2024 (75164)

We lost lock during the SETUP step of ESD_EXC_ETMX, plot attached. ETMX_L3_DRIVEALIGN_L2L (bottom right) had an output but I don't think it should have as the feedback is on ITMX at this point and the excitation hadn't started yet. Should check this before next Tuesday.

ESD_EXC_ETMX log before lockloss:

2023-12-26_15:52:32.263999Z ESD_EXC_ETMX [SETUP.main] ezca: H1:SUS-ETMX_L3_DRIVEALIGN_L2L_TRAMP => 1
2023-12-26_15:52:32.264996Z ESD_EXC_ETMX [SETUP.main] ezca: H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN => 1
2023-12-26_15:52:33.394157Z ESD_EXC_ETMX [SETUP.main] ezca: H1:SUS-ETMX_L3_DRIVEALIGN_L2L_SW1S => 0
2023-12-26_15:52:33.645345Z ESD_EXC_ETMX [SETUP.main] ezca: H1:SUS-ETMX_L3_DRIVEALIGN_L2L => ONLY ON: OUTPUT, DECIMATION

Images attached to this comment
camilla.compton@LIGO.ORG - 11:46, Thursday 04 January 2024 (75171)

Looking at a successful ETMX SETUP state, you can see that there is still a small time where ETMX_L3_DRIVEALIGN_L2L has an output, the IFO just survives the glitch. This happens when the gain is changed from 0 to 1 (to allow excitation through) but before the INPUT is turned off. I've swapped the order of these two lines and added a 1sec sleep between them to make sure that the input is turned off before the gain is ramped to 1. Edit has been saved and will reload during next commisioning period.

Images attached to this comment
Displaying report 1-1 of 1.