Displaying report 1-1 of 1.
Reports until 20:59, Wednesday 27 December 2023
H1 CDS
david.barker@LIGO.ORG - posted 20:59, Wednesday 27 December 2023 (75060)
BS camera needed a reboot before H1 could go into observe

This evening at 17:23 we had a repeat of the BS camera issue we saw on Dec 14th which prevented H1 from going into observe.

To recover I power cycled h1cam26 (BS) with a shutdown/no_shutdown cycle of port 0/35 on sw-lvea-aux. I then killed the camera process on h1digivideo2 (kill -9 as root) to let monit restart the server code.

H1 went into observe just a few minutes after h1cam26 came back online.

I added this event to the ticket which was created on 14th Dec FRS29964