h1hwsmsr (ITMX) offline, ITMX HWS camera is ON

At 23:37 Sun 31 Dec 2023 PST the h1hwsmsr computer crashed. At this time: EDC disconnect count went to 88, Slow Controls SDF (h1tcshwssdf) discon_chans count = 15, GRD DIAG_MAIN cannot connect to HWS channel

The main impact on the IFO is that the ITMX HWS camera cannot be controlled and is stuck in the ON state (taking images at 7Hz).

Time line for camera control:

23:22 Sun 31 Dec 2023 PST Lock Loss, ITMX and ITMY cams = ON
23:37 Sun 31 Dec 2023 PST h1hwsmsr computer crash, no ITMX cam control
04:37 Mon 01 Jan 2024 PST H1 lock, ITMY cam = OFF, ITMX stuck ON

 

Comments related to this report
ryan.short@LIGO.ORG - 10:20, Monday 01 January 2024 (75108)DetChar, OpsInfo

Tagging DetChar in case the 7Hz comb reappears since the ITMX HWS camera was left on for the observing stretch starting this morning at 12:41 UTC.

I also removed ITMX from the "hws_loc" list in the HWS test in DIAG_MAIN and restarted the node at 18:08 UTC so that DIAG_MAIN could run again and clear the SPM diff (tagging OpsInfo). This did not take H1 out of observing.

david.barker@LIGO.ORG - 10:54, Monday 01 January 2024 (75110)

Similar to what I did on 23 Dec 2023 when we lost h1hwsex, I have created a temporary HWS ITMX dummy IOC which is running under a tmux session on cdsioc0 as user=ioc. All of its channels are zero except for the 15 being monitored by h1tcshwssdf which are set to the corresponding OBSERVE.snap values.

EDC and SDF are back to being GREEN.

camilla.compton@LIGO.ORG - 11:33, Wednesday 03 January 2024 (75145)DetChar, TCS

The H1:PEM-CS_MAG_LVEA_OUTPUTOPTICS_Y_DQ channel 74900 shows the 7Hz has been present since ​​​​​ 07:37UTC 01 Jan 2024 when the h1hwsmsr computer crashed. Plan to restart the code turning the camera off during locks 74951 during commisioning today.

In 75124 Jonathan, Erik and Dave replaced the computer and today we were again able to communicate with the camera (needed to use the alias init_hws_cam='/opt/EDTpdv/initcam -f /opt/EDTpdv/camera_config/dalsa_1m60.cfg').  At 18:25-18:40UTC we adjusted from 7Hz to 5Hz, off and left back at 7Hz.  We'll plan to stop Dave's dummy IOC and restart the code later today.  Once this is successful, the CDS team will look at replacing the h1hwsex 75004 and  h1hwsey 73906. Erik has WP 11598

camilla.compton@LIGO.ORG - 16:09, Wednesday 03 January 2024 (75162)

From 23:35UTC these combs are gone, 75159