Continuous Wave (CW) INJ Gain Changes Dropping H1 From Observing (starting at 0037utc)

At 0037utc, H1 was bumped out of OBSERVING due to an SDF change.  The change has been this channel:

I chatted with Louis (phoned him because it is a CAL channel), but he mentions this is not an "online calibration issue", and this has to do with the Continuous Wave Injection.  It also does not appear to be guardian-related.  After chatting with Louis, since Jonathan and Erik are on-site, I just notified them about the issue.

We have currently been OUT of OBSERVING for about 40+min.

Attached is another screenshot with:

Currently, Dave, Erik, & Jonathan are investigating.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 17:29, Tuesday 02 January 2024 (75137)

0128:  Back to OBSERVING!  (thanks to Dave, Erik, Jonathan, and also Louis for my first chat with him).

jonathan.hanks@LIGO.ORG - 17:31, Tuesday 02 January 2024 (75138)
Dave, Erik, Jonathan,

This was caused by an expired leap second file on the h1hwinj1 machine.

It looked like the CW injection process was restarting.  After investigation we noticed that the psinject service was failing, with an error loading the leap second database file.

The solution was to update the tzdata package.  On SL7 this is "yum update tzdata".  After we did that the injection process was able to startup and run.