Reports until 12:42, Wednesday 03 January 2024
H1 CAL
austin.jennings@LIGO.ORG - posted 12:42, Wednesday 03 January 2024 (75149)
Calibration sweep, simulines and BB

I ran a broadband calibration suite at 20:00:40 UTC using pydarm measure --run-headless bb

diag> save /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240103T200048Z.xml
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240103T200048Z.xml saved
diag> quit
EXIT KERNEL

INFO | bb measurement complete.
INFO | bb output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240103T200048Z.xml
INFO | all measurements complete.

 

After this completed I ran the simulines sweep using gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/src/simulines/simulines/settings_h1.ini;gpstime

GPS start: 1388347800

GPS stop: 1388349124

2024-01-03 20:31:46,637 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240103T200944Z.hdf5
2024-01-03 20:31:46,656 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240103T200944Z.hdf5
2024-01-03 20:31:46,668 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240103T200944Z.hdf5
2024-01-03 20:31:46,680 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240103T200944Z.hdf5
2024-01-03 20:31:46,691 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240103T200944Z.hdf5
 

Attached is a screenshot of the calibration monitor, and the pydarm report.

Images attached to this report