At 15:30:48 PST this afternoon h1hwsex crashed again. It had crashed Sat 23 Dec 2023 and was rebooted this Tue 02 Jan 2024. It ran for just about 2 days before crashing again.
Camilla says it is OK to leave the computer off overnight, Erik will replace this computer with a V1 during tomorrow's commissioning break (Fri 05 Jan 2024).
H1 was unlocked at the time of the crash, which means the HWS camera is acquiring images. Camilla confirmed it is OK to leave the camera in this state, it is the ITM cameras which have been causing noise issues.
To green up EDC and SDF, I started the HWS EX dummy IOC on cdsioc0. This is running as user 'ioc' in a tmux session.