Cross Talk in New Endevco

 

We installed a new Endevco into the PEM rack, which replaced Endevco 2. We redid the cross studies for this new Endevco using an accelerometer installed on a shaker and increasing to just before saturation.

We have also now calibrated all of the accelerometers and microphones. Their new calibrations can now be found on the PEM website.  pem.ligo.org

 