Reports until 17:44, Friday 05 January 2024
X1 SUS
ibrahim.abouelfettouh@LIGO.ORG - posted 17:44, Friday 05 January 2024 - last comment - 14:07, Wednesday 17 January 2024(75211)
BBSS M1 Test Stand Initial Transfer Functions

Gabriele, Rahul, Jeff, Oli, Betsy

Find below the initial (no damping loop) transfer functions for the built X1 (Staging Building Test Stand) M1 (Top Mass) BBSS.

These were taken generally following Jeff and Oli's alog 74142, where we used their provided DTT template and tuned the excitation amplitude for each DoF to avoid overflows.

Files are saved on the X1 work station system under ligo/svncommon/SusSVN/sus/trunk/BBSS/X1/BS/SAGM1/Data/

They are dated 01/05/24.

Non-image files attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 14:07, Wednesday 17 January 2024 (75445)

Attached is a pdf of annotated frequency transfer functions for the above measurement.

Find below the Transfer Function resonant peaks frequencies in list form. The second column shows cross coupled freqs i.e. these same frequencies were seen/repeated on different degrees of freedom.

Number of Resonant Peaks Frequency (Hz)
1 0.40625 0.40625
2 0.414062 0.414062
3 0.421875  
4 0.445312  
5 0.453125  
6 0.96875  
7 1.03125  
8 1.15625  
9 1.16406 1.16406
10 1.32031  
11 1.4375  
12 1.54906  
13 1.875  
14 2.59375  
15 2.60156  
16 2.69531  
17 2.9919 2.99219
18 3.84375  

The "UNSURE" table contains some peaks that were somewhat noisy (and not included in the annotation). According to the model, there are supposed to be 2 peaks over 10 Hz (~19Hz and ~31Hz), but due to the noise, I couldn't determine if these were measured - there are definitely peaks in this region at the listed frequencies (none in the "right" spots though).

UNSURE
21.9375
26.75781
37.4375
37.39062

For ease of comparison, below is another table with the modeled peak frequencies. Note that while there are 18 peaks, they do not correspond to the same "18 modes" - this is a pure coincidence.

Mode Number Mode Frequency (Hz)
1 0.412468
2 0.416083
3 0.425915
4 0.473335
5 1.03738
6 1.1633
7 1.16605
8 1.18585
9 1.45428
10 1.46622
11 1.53717
12 1.90606
13 2.64974
14 2.71041
15 3.03671
16 3.85694
17 19.6021
18 31.9402

 This is still a WIP. 

Non-image files attached to this comment