H1 BSC/HAM ISI CPS Sensor Noise Spectra Check (FAMIS task, #25975)

[Measurements attached]

FAMIS LINK:  25975

BSC CPS:  Received following from CPS script terminal output:

NOTE:  If one was to follow the above channel as an example, it would seem several other BSCs had CPS' with spectra similarly high by eye:

HAM CPS:  Looks good.