Reports until 08:55, Wednesday 24 January 2024
H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 08:55, Wednesday 24 January 2024 (75535)
H1 BSC/HAM ISI CPS Sensor Noise Spectra Check (FAMIS task, #25975)

[Measurements attached]

FAMIS LINK:  25975

BSC CPS:  Received following from CPS script terminal output:

NOTE:  If one was to follow the above channel as an example, it would seem several other BSCs had CPS' with spectra similarly high by eye:

HAM CPS:  Looks good.

Non-image files attached to this report