Displaying report 1-1 of 1.
Reports until 13:11, Tuesday 30 January 2024
H1 CAL
louis.dartez@LIGO.ORG - posted 13:11, Tuesday 30 January 2024 (75538)
pydarm reports from start of O4a to late June repaired and prepped for uncertainty budget generation
This work is following up on LHO:73735. 

I've written a script that retroactively fixes the pyDARM parameter issues discussed in LHO:73735. The script lives here on the CDS workstations: /ligo/home/louis.dartez/projects/20240124_script_fix_bad_inis_from_alog_LHO73735/fix_bad_site_inis.py.

Since the pyDARM parameter INI files were initially written in error, anyone trying to process old corresponding to the affected reports' times would be using the wrong IFO models. As such, I've used the script above to fix the affected reports in situ. The original reports have been copied into /ligo/groups/cal/H1/reports/archive/reports_preserved_from_fix_for_LHO73735.