Reports until 13:46, Thursday 25 January 2024
H1 CDS
david.barker@LIGO.ORG - posted 13:46, Thursday 25 January 2024 - last comment - 16:23, Thursday 25 January 2024(75558)
h1susauxey front end computer has a failed power supply

Fil, Jonathan, Erik, Dave:

At EY Fil found h1susauxey has its front panel FAIL LED lit. He tracked the issue down to a failed power supply. This is a redundant dual power supply system.

Strangely this system is not beeping, which is the default behaviour if a power supply unit is inserted but not operational.

The IPMI shell confirms that the system has correctly identified the failure:

ipmi sensor output:

  OK     | (2751) PS1 Status        |           Presence detected           |
  Fail   | (2818) PS2 Status        |     Power Supply Failure detected     |
 

Comments related to this report
david.barker@LIGO.ORG - 13:48, Thursday 25 January 2024 (75559)
david.barker@LIGO.ORG - 16:23, Thursday 25 January 2024 (75562)

Erik replaced the failed power supply with a good spare, status is good

h1susauxey:   OK     | (2751) PS1 Status        |           Presence detected           |
h1susauxey:   OK     | (2818) PS2 Status        |           Presence detected           |