Reports until 07:06, Tuesday 30 January 2024
H1 CDS
erik.vonreis@LIGO.ORG - posted 07:06, Tuesday 30 January 2024 - last comment - 09:49, Tuesday 30 January 2024(75612)
Timing glitch on SUS front ends

There was a timing glitch that affected many models running on corner station front-ends, and the IOPs on h1susb123, h1sush34, h1sush2a, h1sush56.

The timing error is on the order of tens of milliseconds, which is consistent with a Dolphin glitch.  Non-Dolphin front-ends and end station front ends were not affected.

Error was at about Jan 30, 02:45 UTC.  Models are running, but the affected IOPs will need to be restarted.

Comments related to this report
rahul.kumar@LIGO.ORG - 09:49, Tuesday 30 January 2024 (75617)

Dave, Tony, Rahul

SUS and seismic has been recovered after dave gave us a thumbs up.