Displaying report 1-1 of 1.
Reports until 11:25, Tuesday 30 January 2024
H1 ISC (ISC, SUS)
keita.kawabe@LIGO.ORG - posted 11:25, Tuesday 30 January 2024 - last comment - 14:32, Tuesday 30 January 2024(75620)
HAM6 work Jan/29/2024: Alignment of the laser into the new OMC, day 5 (Camilla, Preet, Rahul, Sheila, Betsy, Keita)

day 1 (alog 75548), day 2 (alog 75557), day 3 (alog 75575), day 4 (alog 75601)

Recovery from reboots

After some things were rebooted, we've found that the suspension slider offsets for all OMs, SRM and ZM5 were reverted back to old-ish numbers. I and Camilla manually restored that.

Camilla saw that the beam was not quite back to the old position on one of the HAM7 QPDs but wasn't that bad.

The beam was already on ASC-AS_C but not centered, so I centered it using SRM.

Following that, I had to make a minor tweaking of OM1/2/3 to recenter OMC qpds quickly.

  SRM OM1 OM2 OM3
PIT slider (yesterday/today) 1944.6/1904.6 20/90 0/-80 -590/-550
YAW slider (yesterday/today) -2940.6/-2944.6 650/610 760/760 60/-74
DAC max (yesterday/today) didn't care/57k (18bit DAC) 11k/7.1k 7k/4.5k 9k/6.7k

HAM6 irises are centered

Preet and Sheila recentered the two irises on HAM6. From this point on, these irises are a fiducial for the IFO beam.

OMC trans video beam and OMCR beam dump will be done later this week

LVEA was transitioned to laser safe for HAM3 door removal. We'll continue suspension work in HAM6.

Comments related to this report
sheila.dwyer@LIGO.ORG - 14:32, Tuesday 30 January 2024 (75632)

Here are photos of the beams on the irises.  

Images attached to this comment