cable bracket CB-3 placement difficult and risky to TMS
In D1300007 CB-3 is placed on the -Y side of the TMSX upper structure.  Betsy had moved the bracket, but after looking at the test stand today, I asked Jeff to install it in the original location.

When I look up D1300007, Betsy has a redline drawing, and placed the bracket on the +X side of the TMS upper structure, but this is not accessible from below the upper structure once the ISC table/telescope is in place.  Betsy's redline only claimed interference with the test stand, and there is no test stand interference for CB-3's original location.  Maybe Betsy's redline drawing didn't fully explain her thinking.  I sent her a text but didn't hear back.

Late today, after installing the safety support beams on TMS, it's clear that the real issue with the original placement of CB-3 is that there is only about 6" to access the bracket  from below, and access is between the telescope safety support beams (only 18" apart) - difficult and a risk to TMS.  

If the bracket must stay on the -Y side of the upper structure, my only suggestion is that moving CB-3 toward the QUAD cable brackets might allow slightly better access.  Alternatively, maybe the +X side of the upper structure can be accessed through the structure, so would work?  Either way, an alternative placement should be considered before bringing the TMS telescope under the ISI.
Images attached to this report