Displaying report 1-1 of 1.
Reports until 08:52, Tuesday 06 February 2024
H1 CDS
david.barker@LIGO.ORG - posted 08:52, Tuesday 06 February 2024 (75742)
load_mon_epics running on cdsssh and cdslogin, iocs were restarted

Jonathan, Erik, Dave:

The CDS Load Mon EPICS system was installed on the two sshd servers; cdsssh and cdslogin. Due to a later version of python3 on these machines, the pcaspy code required a modification for the collections module. The IOCs running on cdsssh and cdslogin needed to be restarted, which includes the alarms and locklossalert services.

I have restored the locklossalert settings. The vacuum HAM6 alarms bypass continue through to Mar 11, but the alarm counters were reset so the email sequence has restarted.

I have added CDSSSH and CDSLOGIN to the CDS_HOST_STATS MEDM (see attached)

The new channels will be added to the EDC+DAQ on a target-of-opportunity basis.