Reports until 15:40, Friday 23 February 2024
H1 CAL
dana.jones@LIGO.ORG - posted 15:40, Friday 23 February 2024 - last comment - 06:51, Saturday 24 February 2024(75946)
Error generating report for measurements taken October 11

Dana, Louis

I tried generating the calibration report for report ID 20231011T202627Z but was unable to do so. The following error was returned: 

ValueError: ('There are no common frequency points for the ', 'two transfer functions. Maybe check coherence', ' thresholds.')

For the full error message, see attached txt file.

Non-image files attached to this report
Comments related to this report
hsiang-yu.huang@LIGO.ORG - 06:51, Saturday 24 February 2024 (75954)

I try to investigate this error. It seems that there are no data, frequencies, tf...etc. extracted from both DARMOLG_SS_20231011T202627Z.hdf5 and PCALY2DARM_SS_20231011T202627Z.hdf5.  This make this error appear. For example, freq_meas1 and freq_meas2 in measurement.py L366 and L370 becomes empty, so frequencies variable in L394 is empty. The attached file is to reproduce this error.

Non-image files attached to this comment