Reports until 10:29, Monday 26 February 2024
H1 AOS
david.barker@LIGO.ORG - posted 10:29, Monday 26 February 2024 - last comment - 10:31, Monday 26 February 2024(75963)
h1psl0 models running, ADC was replaced

FRS30546

Richard, Fil, Jonathan, Erik, Tony, Dave:

This morning we power cycled the h1psl0 front-end computer and IO Chassis. At this time the 4th ADC returned to the bus, but we decided it was too risky to go into O4b with a suspect ADC in the PSL. Fil replaced the ADC with a brand new spare.

At this point the Contec6464 card became partially unseated which caused PCIe bus errors, but after this was reseated we have a fully operation h1psl0 with a new 4th ADC card.

old 4th ADC (removed) SN 110203-15
new 4th ADC (installed) SN 230509-58

The old card was given to Erik for testing on the DTS.

Comments related to this report
david.barker@LIGO.ORG - 10:31, Monday 26 February 2024 (75964)

The ADC card failed early Sunday morning, at 04:26:10 PST. This is a classic time for a power company related issue, but I trended the fast MAINS MON channels and cannot find any evidence of a power issue at this time. 

The root cause of the h1psl0 problems is still unknown.