FAMIS 26232
PSL team has been keeping an eye on the listed issues since the PSL had an ADC issue over the weekend (alog75963).
Laser Status:
NPRO output power is 1.823W (nominal ~2W)
AMP1 output power is 67.64W (nominal ~70W)
AMP2 output power is 136.9W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PMC:
It has been locked 0 days, 3 hr 45 minutes
Reflected power = 19.7W
Transmitted power = 106.3W
PowerSum = 126.0W
FSS:
It has been locked for 0 days 0 hr and 56 min
TPD[V] = 0.6414V
ISS:
The diffracted power is around 2.8%
Last saturation event was 0 days 0 hours and 0 minutes ago
Possible Issues:
PMC reflected power is high
FSS TPD is low