Reports until 10:32, Tuesday 27 February 2024
H1 CDS (SUS)
filiberto.clara@LIGO.ORG - posted 10:32, Tuesday 27 February 2024 (75994)
HAM8 Ground Loop Checks

D1900451
E2100504
T1200131

HAM8 ground loops checks completed. All passed. Some cables previously modified per E2100504. This was to resolve known in-chamber ground issues for FC2 Top (BOSEM).

Description     Cable         Location               Notes
FC2 Top         FC2_001    FCES SUS-C1     Pin 13 and shield lifted per E2100504
FC2 Top         FC2_002    FCES SUS-C1     Pin 13 and shield lifted per E2100504
FC2 Middle    FC2_003    FCES SUS-C1     Tested ok
FC2 Bottom   FC2_004    FCES SUS-C1     Tested ok