Following our PSL work on Tuesday (alog76002) during which the PMC alignment and output power changed, I took the opportunity this morning to recalibrate the PSL rotation stage.
Since there have been slow controls restarts in the past weeks, the rotation stage settings had been reset, so I started by putting those back according to trends. The rest of the process went as follows:
| Power in (W) | D | B (Minimum power angle) | C (Minimum power) | |
| Old Values | 102.941 | 1.990 | -24.803 | 0.000 |
| New Values | 103.151 | 1.990 | -24.823 |
0.000 |