Reports until 15:54, Friday 01 March 2024
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 15:54, Friday 01 March 2024 - last comment - 11:16, Friday 08 March 2024(76078)
LOCK_PMC state in SQZ_MANAGER guardian

I made a LOCK_PMC state in SQZ_MANAGER guardian. The LOCK_PMC state is between LOCK_TTFSS and LOCK_SHG states. The LOCK_PMC state is copied from LOCK_SHG state, but I commented out the PZT checker because the PMC_PZT_OK function is not defined now.  

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 14:34, Wednesday 06 March 2024 (76156)

Camilla, Nutsinee

SQZ_MANAGER now takes charge of PMC Guardian. For now we commented out FC related activities in LOCK_OPO_AND_FC state of the SQZ_MANAGER and LOCKING_HD state in SQZ_LO_LR. Look for "NK March 6" for any changes made today in SQZ_MANAGER and SQZ_LO_LR Guardian. These should be reverted when we have the filter cavity back. For now we can lock PMC all the way to LO with SQZ_MANAGER and will automatically relock themselves when IFO kills the PSL. 

nutsinee.kijbunchoo@LIGO.ORG - 11:16, Friday 08 March 2024 (76212)

We have filter cavity. Changes have been reverted.