Displaying report 1-1 of 1.
Reports until 13:02, Monday 04 March 2024
H1 ISC
matthewrichard.todd@LIGO.ORG - posted 13:02, Monday 04 March 2024 - last comment - 13:03, Monday 04 March 2024(76100)
OMC ASC Signs Flipped
Matthew Todd, Elenna Capote

Elenna trended the pos and ang gains of the OMC_ASC back in time, and noticed a few hours ago that the signs of pos-x and ang-y were flipped, which we think corresponds to a time when the OMC Guardian was engaged. We corrected the gain signs in pos-x and ang-y (+, and -,) respectively. We are choosing not to SDF this change at this time.
Comments related to this report
elenna.capote@LIGO.ORG - 13:03, Monday 04 March 2024 (76101)

Here is a screenshot of the trended OMC ASC gains.

Images attached to this comment
Displaying report 1-1 of 1.