Alignment notes

Elenna, Sheila, Gabriele, Jennie W et al.

 

NB:   LHO alog 62110 shows PRG gain plots.

[Jennie W took this log over from Gabriele]

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 15:59, Wednesday 06 March 2024 (76167)OpsInfo

Matt and I checked on the POPAIR checker (added 70882). It was acting correctly, moving to PRMI when RF18 (not RF90) doesn't flash above 95 in the first minute.

Matt lowered the threshold to flashes of RF18 not above 80 in the first 120 seconds. This threshold should be rechecked once we are locking reliably. 