We had issues yesterday with h1dmt1 receiving both gds broadcast streams. Last night John Zweizig and I left it working with only one stream active. Today John and I did two tests. 1. We switched which ethernet port was deactivated. During this test we still saw issues with retransmits during periods with both broadcasts being received. When we disabled the other port that receives the broadcasts things settled down. 2. We rebooted the machine to see if there was some state that was bad and just needed a reboot. This seems to have done the trick. Presently we do not know what exactly was cleared up. We checked the network settings (including buffer sizes, tweaks, ...), software package versions, physical links, ... between h1dmt1 and h1dmt2 and could not find a difference that would explain this behavior. h1dmt1 is running, and the control room should have access to all the DMT products that are needed (range, darm, ...).