Displaying report 1-1 of 1.
Reports until 15:38, Friday 08 March 2024
H1 ISC
sheila.dwyer@LIGO.ORG - posted 15:38, Friday 08 March 2024 - last comment - 19:32, Friday 08 March 2024(76207)
locking today: close to nominal low noise

We've had a large crew in the control room today working on locking:

Comments related to this report
victoriaa.xu@LIGO.ORG - 19:32, Friday 08 March 2024 (76220)SQZ

Naoki, Sheila, Vicky

While damping violins, we re-injected squeezing during OMC_WHITENING, ran SQZ-IFO ASC, and got 3dB of squeezing immediately. Up to almost 4.5dB with this 40x higher CLF power.

Opening the beam diverter, we immediately saw the squeezer in OMC transmission. The CLF_RF3 signal in OMC trans (SQZ-OMC_TRANS_RF3_DEMOD_RFMON) went from -25 (no sqz),  to -8 (just opening bdiverter),  to 0 (after running SQZ_AS42_ASC after resetting no-sqz offsets).

SQZ_MANAGER can successfully take the squeezer to FREQ_DEP_SQZ again. FC-IR handoff works, we adjusted gains according to FC_IR_OLTF to match old loop gain with higher CLF. Adjusted FC_ASC gain. SQZ_ANGLE_ADJUST guardian has the nominal state now as "DOWN" (set using flag=False in sqzparams.py). FC beam spot control left at False.

Images attached to this comment
Displaying report 1-1 of 1.