Displaying report 1-1 of 1.
Reports until 21:27, Friday 08 March 2024
H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:27, Friday 08 March 2024 - last comment - 09:55, Monday 11 March 2024(76223)
Simple OMC dither alignment working - very little headroom on OMC SUS T2 T3

Since we have a new OMC, we need to find the best optical gain spot on the new OMC.

To that end I closed the OMC ASC dither loops iwth a simple diagonal matrix (OM3-->OM3 and OM1-->OMC_SUS). It did converge with very low gain, but to a spot with not much headroom on the OMC_SUS (we are at 115000ct out of 131000cts on T2 and T3).

In that setting I reset the H1:ASC-OMC_[A/B]_[PIT/YAW]_OFFSET offsets, so right now we can lock to that spot with either dither or QPD.

Next: hunt for best optical gain around this spot.

 

Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 18:53, Friday 08 March 2024 (76225)

Just as with the last OMC the optimal spot optical gain seems to be slightly different from the dither target. Did some manual optimisation to reach the attached QPD offsets.

Images attached to this comment
stefan.ballmer@LIGO.ORG - 09:55, Monday 11 March 2024 (76243)

Updated the dither input matrix  H1:OMC-ASC_DACTMAT  in SDF.

Images attached to this comment
Displaying report 1-1 of 1.