Guardian changes useful for vent recovery

This is a summary of information that is spread across different alogs in the last few days.  When recovering from a vent, in which the green camera reference may have been lost when the gate valves are actuated, these are some useful steps and guardian changes.

We have made and reverted these changes this week, I'm not sure if we've reverted the change to the INCREASE_FLASHES timer.

Comments related to this report
ryan.short@LIGO.ORG - 10:36, Monday 11 March 2024 (76251)ISC

I've reverted the increased INCREASE_FLASHES timer; it is now back to 2 minutes during LOCKING_ARMS_GREEN.