Reports until 12:41, Monday 11 March 2024
H1 PSL
anthony.sanchez@LIGO.ORG - posted 12:41, Monday 11 March 2024 (76260)
PSL Status Report - Weekly

FAMAS 26234 PSL Status Report -Weekly

 

Laser Status:
    NPRO output power is 1.821W (nominal ~2W)
    AMP1 output power is 67.71W (nominal ~70W)
    AMP2 output power is 140.0W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN

PMC:
    It has been locked 10 days, 20 hr 55 minutes
    Reflected power = 16.4W
    Transmitted power = 109.5W
    PowerSum = 125.9W

FSS:
    It has been locked for 0 days 0 hr and 39 min
    TPD[V] = 0.8063V

ISS:
    The diffracted power is around 2.6%
    Last saturation event was 0 days 0 hours and 40 minutes ago


Possible Issues: None