Mod depth up down test, cold OM2, 54.3 W input - March 11, 2024
Jennie, Craig

Today we reran the mod-depth up down tests.  We are not fully trusting these numbers because we suspect we are clipping a bit on IM4_TRANS, which might artificially raise all of our estimated PRGs, including those for RF9 and RF45.
Additionally, there was obvious thermalization still happening during the measurement.  Still, the first pass measurement is useful for up to 10% estimates?
We should rerun after we recenter on IM4.

PRGs
9 MHz PRG = 85.6
45 MHz PRG = 36.6
Carrier PRG = 50.4

REFL ratios
9 MHz reflection ratio = 0.309
45 MHz reflection ratio = 0.268
Carrier reflection ratio = 0.055

Table of relative powers
Channels9 MHz45 MHzCarrier
H1:IMC-PWR_IN_OUT160.0130.0150.972
H1:IMC-IM4_TRANS_NSUM_OUT160.0130.0150.972
H1:LSC-REFL_A_LF_OUT160.0650.0650.870
H1:LSC-REFL_B_LF_OUT160.0630.0620.874
H1:LSC-POP_A_LF_OUT160.0220.0110.967
H1:ASC-POP_A_NSUM_OUT160.0210.0110.968
H1:ASC-POP_B_NSUM_OUT160.0210.0110.968
H1:ASC-AS_C_NSUM_OUT160.1810.5210.298
H1:ASC-OMC_A_NSUM_OUT160.1740.6370.189
H1:ASC-OMC_B_NSUM_OUT160.1800.5650.255
H1:ASC-X_TR_A_NSUM_OUT160.0080.0090.983
H1:ASC-X_TR_B_NSUM_OUT160.0080.0090.983
H1:ASC-Y_TR_A_NSUM_OUT160.0090.0090.983
H1:ASC-Y_TR_B_NSUM_OUT160.0090.0090.983
EDIT: We forgot where the POP beam diverter was, so I'm also posting some MEDMs and Guardian code snippets of where and how to reopen that beam diverter. We have left the POP beam diverter open for now.
Images attached to this report
Non-image files attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 10:02, Tuesday 12 March 2024 (76289)

For the 9 MHz PRG of 85.6 the nominal level on POPAIR_B_RF18 I phase PD is 1577 counts.

For the 45 MHz PRG of 36.6 the nominal level on POPAIR_B_RF90 I phase PD is 399 counts.