Jennie, Craig Today we reran the mod-depth up down tests. We are not fully trusting these numbers because we suspect we are clipping a bit on IM4_TRANS, which might artificially raise all of our estimated PRGs, including those for RF9 and RF45. Additionally, there was obvious thermalization still happening during the measurement. Still, the first pass measurement is useful for up to 10% estimates? We should rerun after we recenter on IM4. PRGs 9 MHz PRG = 85.6 45 MHz PRG = 36.6 Carrier PRG = 50.4 REFL ratios 9 MHz reflection ratio = 0.309 45 MHz reflection ratio = 0.268 Carrier reflection ratio = 0.055 Table of relative powers
| Channels | 9 MHz | 45 MHz | Carrier |
|---|---|---|---|
| H1:IMC-PWR_IN_OUT16 | 0.013 | 0.015 | 0.972 |
| H1:IMC-IM4_TRANS_NSUM_OUT16 | 0.013 | 0.015 | 0.972 |
| H1:LSC-REFL_A_LF_OUT16 | 0.065 | 0.065 | 0.870 |
| H1:LSC-REFL_B_LF_OUT16 | 0.063 | 0.062 | 0.874 |
| H1:LSC-POP_A_LF_OUT16 | 0.022 | 0.011 | 0.967 |
| H1:ASC-POP_A_NSUM_OUT16 | 0.021 | 0.011 | 0.968 |
| H1:ASC-POP_B_NSUM_OUT16 | 0.021 | 0.011 | 0.968 |
| H1:ASC-AS_C_NSUM_OUT16 | 0.181 | 0.521 | 0.298 |
| H1:ASC-OMC_A_NSUM_OUT16 | 0.174 | 0.637 | 0.189 |
| H1:ASC-OMC_B_NSUM_OUT16 | 0.180 | 0.565 | 0.255 |
| H1:ASC-X_TR_A_NSUM_OUT16 | 0.008 | 0.009 | 0.983 |
| H1:ASC-X_TR_B_NSUM_OUT16 | 0.008 | 0.009 | 0.983 |
| H1:ASC-Y_TR_A_NSUM_OUT16 | 0.009 | 0.009 | 0.983 |
| H1:ASC-Y_TR_B_NSUM_OUT16 | 0.009 | 0.009 | 0.983 |
For the 9 MHz PRG of 85.6 the nominal level on POPAIR_B_RF18 I phase PD is 1577 counts.
For the 45 MHz PRG of 36.6 the nominal level on POPAIR_B_RF90 I phase PD is 399 counts.