Ops Day Shift End

TITLE: 03/12 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: None
SHIFT SUMMARY: Tuesday maintenance today, mostly a lot of VAC and CDS work. We has issues getting ETM and TMS model working(76305), but we were finally able to get them up and are currently working on locking green arms.
LOG:

15:00UTC Starting Tuesday maintenance
15:38 Turned sensor correction off                                                                      

Start Time System Name Location Lazer_Haz Task Time End
15:15 ISC TJ, Georgia, Matt, Trent LVEA - ISCT1 yes(local) Realigning green beatnote - TJ out 15:50 16:01
15:15 FAC Karen EY n Tech clean 15:53
15:16 FAC Kim EX n Tech clean 16:20
15:24 HWS Camilla, Graeme, TJ EX YES HWS table work 18:20
15:28 FAC Mitchell LVEA - West bay n Labelling things 17:47
15:30 EE Fil H2 n Looking at humidity sensors 16:23
15:38 VAC Gerardo, Jordan Bier Garten n Purge air, Jordan out 17:07, Travis out 18:40, Janos out 18:49 19:00
16:01 CDS Dave remote n WP11766 New h1iopsusey model 20:23
16:02 SUS/ISI Oli, Jeff,Dave CR n WP11743 New SUS & ISI models ETMX, ETMY 20:23
16:03 DMT Dan MSR n WP11765 Reboot DMT servers 18:46
16:03 DAQ Dave remote n Reboot DAQ for SUS/ISI model changes 20:23
16:08 FAC Karen, Kim HAM Shack n Tech clean 16:35
16:09 CDS Jonathan office n WP11761 Upgrade FCES network switch 17:23
16:14 CDS Jonathan remote n Upgrading FCES switch firmware 16:55
16:34   Richard LVEA - GV2 n Meeting up with Fil 16:55
16:36 IAS Ryan C LVEA - Beer garden n Measuring with FARO 18:29
16:45 SQZ Daniel, Nutsinee HAM7 n Measuring SQZ rack electronics 18:19
17:02 FAC Kim High Bay n Tech clean 18:48
17:04 FAC Karen OptLab, VacPrep, LVEA n Tech clean 18:16
17:07 VAC Jordan, Eric EX YES Hooking up RGA 18:07
17:25 EE Marc, Fernando LVEA n Helping Gerardo 18:35
18:36 TCS Camilla, Fernando LVEA n Looking at TCS controls 19:01
20:00 FAC Bubba EY n Checking water tank 20:24
20:13 - Gabriele EX,EY n Becoming healthier 22:13
20:56 - Janos, Graeme, Craig MX n tour 21:56
21:01 EE Gerardo, Jordan EY,ex n replacing batteries for solar panels 22:01
22:21 SQZ Nutsinee LVEA - SQZT0 n Taking measurements 22:26
22:22 VAC Travis MX n Turn off turbo pump 22:52
22:35 SQZ Nutsinee LVEA - SQZT0 n More measurements 23:05