Reports until 16:39, Tuesday 12 March 2024
LHO General
nyath.maxwell@LIGO.ORG - posted 16:39, Tuesday 12 March 2024 (76308)
Internet Path Redundancy Restoration WP11759
General Compute work successful and complete. Split the fibre optic pair that was a single pair - 2 strand connection to ESNet and split the fiber to 2 single strand full duplex circuits to ESNet. We now have BGP Peer redundancy and Seattle route as preference. We are using BiDi connectors now over standard SFP+. One route to Boise and one route to Seattle. Seattle preferred due to latency, Boise is redundant. Duration of total outage was approximately 30 minutes, and duration to full restoration was about one hour. 

1500: Work Started 
15:15 Internet connection cut
15:45 Initial restoration achieved, but not the Seattle link.
16:15 Seattle link is restored when fiber patch found incorrectly connected. This was corrected and full circuit restoration was seen.
16:30 All secure from this evolution. Hands off all systems check shows complete operation, BGP peering to Seattle that is established, and IP Flows are in the Seattle route destinations.